Diagram Fm 200 Fire Suppression System
Fm200 firesuppressionreleasesystem theengineersadvice subscribe my channel.
Diagram fm 200 fire suppression system. Ul ulc fmrc require multiple tiers of nozzles for heights above 16 0 4 88 m. This specification outlines the requirements for a cross zoned detection and total flooding fm 200 fire suppression system. Fm 200 fire suppression systems protect everything from computer rooms data centres telecommunications facilities and switch gear to military vehicles high tech medical applications and pleasure craft to. We provide an immediate response to clean agent fire suppression system discharges whether accidental or from a fire to get your system back into service as quickly as possible.
Fm 200 hfc 227ea is formed from the elements carbon fluorine and hydrogen cf3chfcf3 heptafluoropropane. What is an fm 200 fire suppression system. Fm 200 system installations testing more. To schedule fm 200 system services in the new jersey or delaware area contact confires online or call 888 228 0917.
Within 10 seconds it will discharge and suppress a fire immediately. The work described in the specification consists of all labor materials equipment and services necessary and required to complete and test the system. Fm 200 fire suppressant hfc 227ea can be safely used where. Also known as hfc227ea this is a waterless fire protection system that works wonders when under pressure.
For speed in suppressing fires reducing damages saving on floor space and allowing visibility fike is the clear choice. Hello guys learn fm 200 fire suppression release system wiring and operation. After an fm 200 system discharge the fm 200 cylinder s should be returned to an authorized. Fm 200 1 1 1 2 3 3 3 heptafluoropropane cf3chfcf3 is a colorless odorless gas low in toxicity electrically non conductive leaves no residue and is an extremely effective fire suppression agent.
Will not be approved for factory mutual installations. Heptafluoropropane more commonly known as fm 200. Fire detection and fm 200 suppression system a. Fm 200 systems using concentrations below 6 25 are not ul ulc listed nor factory mutual approved.
For more information please see below http www ife co th. Fm 200 is a chemical agent used primarily in total flooding systems and has been installed in over 200 000 systems worldwide. The primary extinguishing mechanism of fm 200 is heat absorption with a secondary chemical contribution from the thermal decomposition of fm 200 in the flame.