Direct Vent Furnace Sidewall Vent Kit
Combustion products are discharged outdoors through the wall vent.
Direct vent furnace sidewall vent kit. Vent kit is not for use with single pipe indirect vent installations. The 2 3 side wall direct vent kit is for use with high efficient condensing furnaces. Failure to follow this warning could result in fire personal injury or death. The york etc used a stainless flex pipe and not b vent.
B vent is not airtight. The vent kit must terminate outside the structure and can be installed with the intake and exhaust pipes located side by side or with one pipe above the other. This eliminates the expense of a vent. The space saving direct vent furnace design mounts to an exterior wall and the adjustable vent assembly adjusts to fit walls from 4 1 2 in.
This vent kit is to be used with 2 vent systems. Air necessary for combustion is drawn into the. Next b vent is for negative pressure draft systems only. Warning do not use the concentric vent kit for anything other than a category iv furnace.
This is an alternative to the standard two pipe intake vent shown in the basic furnace installation instructions. Do not use this kit to vent category i ii or iii furnaces do not apply to non condensing furnaces. I0 635a september 2013 warning this vent kit is only to be used for venting category iv condensing furnaces. This kit is not intended for use with single pipe indirect vent installations.
So even if your furnace were to be approved for side wall venting b vent is not the proper type of vent pipe to use. For use with direct vent furnace side wall vent kit function this vent kit is only to be used for venting category iv condensing furnaces do not use this kit to vent category i ii or iii furnaces do not apply to non condensing furnaces do not use for roof top venting how can we improve our technical specifications. Refer to the furnace installation instructions for intake vent pipe sizing information. Do not use for roof top venting use this kit for side wall venting only.
Direct vent counterflow the forced air circulation comfort heating system uses only outside air for combustion as the burners are completely sealed within the combustion chamber. Direct vent furnace side wall vent kit 0170k00001s. Cvent 3 is for use with 3 in. The vent kit must terminate outside the structure and may be installed with the intake and exhaust pipes located side by side or with one pipe above the other.
All vent caps include a built in bird guard. A sidewall power venter can be installed. It provides an alternative to the traditional two pipes out the wall option.